Home » Laser Machine » Co2 Laser Machine » CO2 Laser engraving machine » 42/57 Stepper Motor Driver M542C Common Problems and Solutions
Content

Common problems and solutions:
Phenomenon | possible problem | solution |
Motor does not turn | The power light is off | normal power supply |
Current setting is too small | According to the rated current of the motor, select the appropriate | |
Drive is protected | After troubleshooting, power on again | |
enable signal is low | This signal is pulled high or not connected | |
control signal problem | Check whether the amplitude and width of the control signal meet the requirements | |
Motor turning wrong | Motor wiring is wrong | Swap two wires of the same phase of the motor arbitrarily |
Motor wire is broken | Check and match | |
Alarm light on | Motor wiring is wrong | Check wiring |
Voltage too high or too low | Check the supply voltage | |
Damaged motor or drive | Replace the motor or drive | |
inaccurate location | Signal is disturbed | Eliminate distractions |
The shielding ground is not connected or not connected well | Reliable grounding | |
segmentation fault | paired segment | |
Current is too small | Properly increase the current | |
control signal problem | Check whether the control signal meets the timing requirements | |
Motor stalls when accelerating | Acceleration time is too short | Properly increase the acceleration time |
Motor torque is too low | Choose a high-torque motor | |
Voltage is too low or current is too low | Appropriately increase the voltage or set a larger current |